title: "Thevenin"
canonical_url: https://developer.repebble.com/pebbleos/docs/libraries/fuel_gauge/models/thevenin/
last_updated: 2026-11-13
sdk_version: 4.44
---
# Thevenin

Source: https://developer.repebble.com/pebbleos/docs/libraries/fuel_gauge/models/thevenin/

`FUEL_GAUGE_THEVENIN` estimates the SOC with an extended Kalman filter over a Thevenin equivalent circuit: the cell’s \(R\_0\) in series with one RC polarization pair. Coulomb counting predicts the SOC, and the measured terminal voltage corrects it, so the estimate doesn’t drift with current errors nor jump with the load.

## Model

The cell is an equivalent circuit: the OCV of the [cell](https://developer.repebble.com/pebbleos/docs/libraries/fuel_gauge/introduction.md#fuel-gauge-cell), in series with its resistor \(R\_0\) and one resistor-capacitor pair \(R\_1 \parallel C\_1\).

![OCV source in series with R0 and the R1 parallel C1 pair](https://developer.repebble.com/pebbleos/docs/images/thevenin_circuit.svg)
_Thevenin equivalent circuit of the cell, with the current \(i\) positive when discharging._

With \(z\) the SOC (0 to 1), \(i\) the current (positive when discharging), \(Q\) the capacity in coulombs and \(v\_1\) the voltage across the RC pair, the terminal voltage \(v\) follows

 \[\begin{split}\begin{aligned} \dot z &= -\frac{i}{Q} \\ \dot v\_1 &= -\frac{v\_1}{\tau\_1} + \frac{i}{C\_1}, \qquad \tau\_1 = R\_1 C\_1 \\ v &= \mathrm{OCV}(z) - v\_1 - R\_0\, i \end{aligned}\end{split}\]

\(R\_1 \parallel C\_1\) is the slower polarization (charge transfer and diffusion). It builds up under load and relaxes with the time constant \(\tau\_1\) once the load is removed. Without the pair (\(R\_1 = 0\)), the model is \(R\_0\) alone.

A single RC pair keeps the model small and its fit well conditioned. Dynamics much faster than the sample interval can’t be resolved anyway, so more pairs only pay off with faster sampling.

### Discretization

Samples come at times \(t\_k\), with \(\Delta t\_k = t\_k - t\_{k-1}\). The current \(i\_k\) is a single sample taken at \(t\_k\), and it is held over the whole interval \((t\_{k-1}, t\_k]\). For a constant current, the RC equation has the exact solution

 \[v\_{1,k} = a\_k\, v\_{1,k-1} + R\_1 (1 - a\_k)\, i\_k, \qquad a\_k = e^{-\Delta t\_k / \tau\_1}\]

and coulomb counting gives

 \[z\_k = z\_{k-1} - \frac{i\_k\, \Delta t\_k}{Q}.\]

The estimator and the fit use these same equations, so a model fitted on bench logs behaves the same way in the firmware, whatever the sample interval.

### Temperature

Resistances grow as the cell gets colder. Both \(R\_0\) and \(R\_1\) are scaled by

 \[s(T) = e^{\kappa\,(25 - T)}\]

with \(T\) in °C, clamped to -20..60 °C, and \(\kappa\) the resistance temperature coefficient. The OCV and the capacity don’t depend on temperature.

## Filter

The estimator is an extended Kalman filter over the state \(x = [z, v\_1]^T\) and its covariance \(P\). Each measurement \((v\_k, i\_k, T\_k)\) goes through a prediction and a correction.

**Predict** (coulomb counting), with \(g\_k\) the sensitivity of the state to the current:

 \[\begin{split}\begin{aligned} x\_k^- &= \begin{bmatrix} z\_{k-1} \\ a\_k\, v\_{1,k-1} \end{bmatrix} + g\_k\, i\_k, \qquad g\_k = \begin{bmatrix} -\Delta t\_k / Q \\ R\_1 s(T\_k) (1 - a\_k) \end{bmatrix} \\ P\_k^- &= F\_k P\_{k-1} F\_k^T + g\_k g\_k^T \sigma\_i^2, \qquad F\_k = \begin{bmatrix} 1 & 0 \\ 0 & a\_k \end{bmatrix} \end{aligned}\end{split}\]

The process noise comes only from the current error \(\sigma\_i\) (`current_noise`). Both states are driven by the same current, so its covariance is the outer product of \(g\_k\) with itself. \(\sigma\_i\) is how far the single sample \(i\_k\) can be from the true average current of the interval. With sparse samples and a bursty load, this dominates over the error of the current measurement itself.

**Correct** (voltage). The predicted terminal voltage and its linearization:

 \[\hat v\_k = \mathrm{OCV}(z\_k^-) - v\_{1,k}^- - R\_0\, s(T\_k)\, i\_k, \qquad H\_k = \begin{bmatrix} \mathrm{OCV}'(z\_k^-) & -1 \end{bmatrix}\]

 \[\begin{split}\begin{aligned} e\_k &= v\_k - \hat v\_k \\ S\_k &= H\_k P\_k^- H\_k^T + \sigma\_v^2 \\ K\_k &= P\_k^- H\_k^T / S\_k \\ x\_k &= x\_k^- + K\_k\, e\_k \\ P\_k &= P\_k^- - K\_k S\_k K\_k^T \end{aligned}\end{split}\]

\(e\_k\) is how far the measured voltage is from the predicted one, and \(S\_k\) its expected variance. \(\sigma\_v\) (`voltage_noise`) covers the voltage measurement error and the model error.

How much the correction moves the SOC depends on the OCV slope \(\mathrm{OCV}'\), but the gain on \(z\) isn’t proportional to it. Ignoring \(v\_1\), the gain is \(K\_z = P\_{zz}\,\mathrm{OCV}' / (\mathrm{OCV}'^2 P\_{zz} + \sigma\_v^2)\): it first rises with the slope, then falls as \(1/\mathrm{OCV}'\) where the curve is steep, since there a voltage error is a small SOC error. What rises with the slope is \(H K\), the fraction of the voltage error \(e\_k\) the correction removes. With \(\sqrt{P\_{zz}} = 2\%\) and \(\sigma\_v = 15\) mV, on the OCV curve of a small Li-po cell charged to 4.45 V:

| 

Where

 | 

\(\mathrm{OCV}'\) (V)

 | 

\(K\_z\) (1/V)

 | 

\(H K\)

 |
| --- | --- | --- | --- |
| 

plateau, 7.5-10%

 | 

0.43

 | 

0.58

 | 

0.25

 |
| 

near full, 95-100%

 | 

1.1

 | 

0.62

 | 

0.68

 |
| 

near empty, 0-1%

 | 

26.6

 | 

0.038

 | 

1.00

 |

So on the flat plateau the filter mostly keeps the coulomb count, and where the curve is steep it follows the voltage almost entirely. Current gain and offset errors, which make pure coulomb counting drift without bound, are corrected continuously.

**Charge complete.** When the charger terminates, the SOC is set to 1 with a small uncertainty.

## Parameters

`struct pbl_fuel_gauge_estimator` holds them. In the firmware they come from Kconfig, through `PBL_FUEL_GAUGE_ESTIMATOR_KCONFIG`:

| 

Parameter

 | 

Kconfig

 |
| --- | --- |
| 

\(R\_1\)

 | 

`FUEL_GAUGE_THEVENIN_RC_MILLIOHM`

 |
| 

\(\tau\_1\)

 | 

`FUEL_GAUGE_THEVENIN_RC_TAU_MS`

 |
| 

\(\kappa\)

 | 

`FUEL_GAUGE_THEVENIN_R_TEMP_COEFF_PPM`

 |
| 

\(\sigma\_v\)

 | 

`FUEL_GAUGE_THEVENIN_VOLTAGE_NOISE_UV`

 |
| 

\(\sigma\_i\)

 | 

`FUEL_GAUGE_THEVENIN_CURRENT_NOISE_UA`

 |

[Characterization](#fuel-gauge-characterization) below describes how \(R\_1\), \(\tau\_1\) and \(\kappa\) are measured and fitted, together with the cell.

## Limitations

- The OCV is modelled at 25 °C, and the capacity doesn’t depend on temperature. Only the resistances do.

- \(R\_0\) and \(R\_1\) don’t depend on the SOC, while those of a real cell rise near empty. Close to empty, the model then underestimates the drop under load.

- There is no OCV hysteresis between charge and discharge. The fitted curve sits between the two branches when the logs include charging.

- Capacity fade with aging is not tracked.

## Characterization

This section describes how to measure a cell and fit this model to it: what to measure, with which instrument, and how to check the result. Models come only from our own measurements. The method doesn’t depend on an instrument; [Characterization tools](https://developer.repebble.com/pebbleos/docs/libraries/fuel_gauge/tools.md) has the tools that implement it.

The flow is:

1. Charge the cell as the product does, rest it, and discharge it in pulses down to the cutoff, logging voltage, current and temperature.

2. Fit the model to the log with `tools/fuel_gauge/fuel_gauge.py fit`, which writes a model file and prints the board’s battery node properties and Kconfig defaults.

3. Check it, with `fuel_gauge.py replay` on the bench log, then on a second cell or on logs from the device.

### Full and empty

The model’s SOC runs from 0 to 1 between two points that the procedure defines, so they have to be the product’s.

- **Full** (\(z = 1\)) is where the charger terminates. Charge with the product’s charge profile: the same termination voltage, charge current and termination current as the device (the battery node in the board’s devicetree). A different profile moves “full” and changes the capacity.

- **Empty** (\(z = 0\)) is where the discharge stops: the cutoff voltage, under the load of the last pulses. The estimator reports 0% at \(z = 0\), and the battery service treats 0% while unplugged as critical, so the cutoff defines where the device reports empty. Choosing it is a product decision: a lower cutoff gives more runtime, a higher one leaves more margin before the cell’s protection or the PMIC’s brownout.

The capacity \(Q\) is the charge delivered between these two points, at the procedure’s discharge rates.

### Instrument

The procedure needs a programmable load and a charger (or a way to swap between them), and logs of the following, with the reasons:

![Cell with a current sense in series to a charger or load, 4-wire voltage](https://developer.repebble.com/pebbleos/docs/images/measurement_setup.svg)
_sense at its terminals and a temperature sensor, all read by a logger

Measurement setup. The force path runs through the current sense to the charger or load, while the voltage is sensed separately at the cell terminals. Voltage, current and temperature are logged together._

- **Voltage at the cell.** Everything between the cell and the voltage sense point ends up in \(R\_0\). Use 4-wire sensing at the cell terminals, or measure the fixture’s resistance \(R\_\text{fixture}\) between the cell and the sense point. The device measures at its own PMIC, through its own path \(R\_\text{device path}\), so the model’s resistance is

- **Current, with a known error.** The fit takes the SOC from coulomb counting, so a current error becomes a capacity error, and through it an error on the SOC of every OCV point. With a gain error \(\epsilon\_i\) and an offset \(i\_\text{off}\) over a test of length \(T\):

- **Sample rate** of about 1 Hz. The fit sees \(R\_0\) in the voltage step at each pulse edge and \(\tau\_1\) in the relaxation after it, which takes tens of seconds; the samples have to resolve both.

- **Temperature** of the cell, or at least of the ambient, since the resistances depend on it. Characterize at a stable temperature, away from heat sources.

### Test profile

A constant-current discharge can’t separate the OCV from the resistive drops: at a constant \(i\), \(R\_0 i\) and \(R\_1 i\) are just offsets on the OCV. Pulses with rests make every parameter visible:

![../../../../_images/fuel-gauge-pulse.svg](https://developer.repebble.com/pebbleos/docs/images/fuel-gauge-pulse.svg)

- The **step** at each pulse edge is \(R\_0\, s(T)\, \Delta i\).

- The **relaxation** after a pulse of current \(i\) and length \(t\_p\) is

- The **end of each rest** is close to the OCV at that SOC, as long as the relaxation has died out.

The profile’s parameters, and what sets them:

| 

Parameter

 | 

Default

 | 

Why

 |
| --- | --- | --- |
| 

Initial rest

 | 

30 min

 | 

The log has to start from a full cell at rest: right after charging, the polarization of the CV phase is still relaxing.

 |
| 

Pulse depth

 | 

2% of \(Q\)

 | 

Each pulse gives one OCV point, so 2% gives about 50, at least two per interval of a 21-25 point OCV grid. Shallower pulses lengthen the test.

 |
| 

Pulse rate

 | 

0.5C

 | 

The step \(R\_0 \Delta i\) has to stand well above the voltage resolution (about 100 mV for a 70 mAh cell with a 3 Ω \(R\_0\)), without heating the cell.

 |
| 

Pulse length

 | 

depth / rate, 144 s

 | 

At least about \(\tau\_1\), so the RC pair charges enough for its relaxation to show.

 |
| 

Rest

 | 

until relaxed

 | 

See below.

 |
| 

Tail

 | 

quarter rate, 4× long

 | 

Near the cutoff, from 0.2 V above it under load: a lighter load draws more charge before the cutoff, closer to the device’s.

 |

**Rest criterion.** A rest should end once the remaining relaxation is below the error the OCV points can tolerate. For an exponential, the voltage still to relax is \(\tau\_1\, |dv/dt|\), so with \(\tau\_1\) up to 200 s, leaving less than 1 mV takes \(|dv/dt| \< 5\) µV/s, about 0.3 mV/min. Measure the slope over a few minutes, as it is below the voltage resolution over a single second. An instrument that can’t end a step on a condition needs a fixed rest long enough for the slowest expected \(\tau\_1\): 15 minutes is 4.5 to 9 time constants for \(\tau\_1\) of 100 to 200 s, and about 14 for 65 s.

The discharge takes about 15 hours, plus the charge.

### Fit

```
python tools/fuel_gauge/fuel_gauge.py fit mycell_25c.csv --name mycell -o mycell.json \--grid 0 0.01 0.02 0.03 0.05 0.08 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 \0.5 0.55 0.6 0.65 0.7 0.75 0.8 0.85 0.9 0.95 1
```

The capacity, \(R\_0\) and the OCV curve go in the board’s `simple-battery` node (`charge-full-design-microamp-hours`, `factory-internal-resistance-micro-ohms` and `ocv-capacity-table-0`). The RC pair and the temperature coefficient go in the board’s `Kconfig.defconfig`, as defaults of `FUEL_GAUGE_THEVENIN_RC_MILLIOHM`, `FUEL_GAUGE_THEVENIN_RC_TAU_MS` and `FUEL_GAUGE_THEVENIN_R_TEMP_COEFF_PPM` under `if FUEL_GAUGE_THEVENIN`, so they only apply where the model is used. The devicetree takes the OCV curve in whole percents, so the grid points must be whole percents too.

By default each log starts full (`--start-soc 1`), and the first log ends empty (`--end-soc 0`), which defines the capacity. `--capacity-ah` sets it instead. The fit prints the parameters, the voltage residual, and a warning for any SOC range the logs don’t cover. `fit --help` has the options.

To fit the temperature coefficient, run the procedure at other temperatures too (e.g. 5 °C and 40 °C, in a climate chamber) and pass all logs to `fit`. The first log defines the capacity, so put the 25 °C one first.

#### Known SOC path

The fit needs the SOC at every sample, which coulomb counting provides when the log starts from a known state:

 \[z\_k = z\_0 - \frac{1}{Q} \sum\_{m \le k} i\_m\, \Delta t\_m.\]

A log that starts full (\(z\_0 = 1\)) and ends at the cutoff (\(z\_\text{end} = 0\)) defines the capacity:

 \[Q = \frac{\sum\_k i\_k\, \Delta t\_k}{z\_0 - z\_\text{end}}.\]

#### Linear least squares

For a fixed \(\tau\_1\) and \(\kappa\), the terminal voltage is linear in all the other unknowns. Writing the OCV as linear interpolation over a grid of SOC points \(z\_1 \< \dots \< z\_n\),

 \[\mathrm{OCV}(z\_k) = \sum\_j w\_j(z\_k)\, \mathrm{OCV}\_j\]

where \(w\_j\) are hat functions (each sample has at most two non-zero weights), the model becomes

 \[v\_k = \sum\_j w\_j(z\_k)\, \mathrm{OCV}\_j - R\_0\, s(T\_k)\, i\_k - R\_1\, \ell\_k\]

with \(\ell\) the first-order lag of the [discretization](#fuel-gauge-discretization), \(\ell\_k = a\_k \ell\_{k-1} + (1 - a\_k)\, s(T\_k)\, i\_k\). Stacking all \(N\) samples gives an overdetermined linear system \(A\theta \approx v\) in \(\theta = [\mathrm{OCV}\_1 \dots \mathrm{OCV}\_n, R\_0, R\_1]\).

Three constraints make the solution physical:

- **Increasing OCV.** The OCV points are written as a base voltage plus steps, \(\mathrm{OCV}\_j = u\_1 + \sum\_{m=2}^{j} u\_m\), i.e. \(\mathrm{OCV} = T u\) with \(T\) a lower-triangular matrix of ones, and every step \(u\_m \ge 0.1\) mV. The estimator requires a strictly increasing curve, and a non-increasing one would make the SOC ambiguous.

- **Non-negative resistances** , \(R\_0, R\_1 \ge 0\).

- **Smoothness.** A penalty \(\lambda \lVert D\_2 T u \rVert^2\) on the second difference of the OCV fills SOC ranges without data and damps noise, with \(\lambda = \text{smoothing}^2 N / n\) (`--smoothing`). The data term grows with \(N\), so scaling \(\lambda\) with it keeps the penalty’s effect independent of the log length.

#### Nonlinear parameters

\(\tau\_1\) and \(\kappa\) enter nonlinearly. For each candidate, the linear problem is solved and its residual kept (variable projection), so the outer search only explores one or two dimensions:

- \(\tau\_1\): bounded 1-D minimization of the mean squared residual over \(\ln \tau\_1 \in [\ln 5, \ln 5000]\) s.

- \(\kappa\): when the logs span at least 10 °C, a bounded 1-D minimization over \([0, 0.08]\) 1/°C, each candidate with its best \(\tau\_1\). Otherwise it is fixed at 0.03 1/°C, a typical value for Li-ion cells.

#### Grid

The default grid is 21 evenly spaced points (`--grid-points`, or `--grid` for explicit points). The OCV bends sharply near empty, so a grid denser there, like above, fits the end of the discharge noticeably better. Grid points that no sample falls next to are reported, since their OCV comes only from the smoothness penalty.

### Validate

- **Residual.** Around 5-10 mV RMS is a good fit. Large maximum residuals tend to sit at the very end of the discharge, where the OCV bends sharply; a denser grid there helps.

- **Coverage warnings.** An SOC range without data means the procedure didn’t reach it, typically near full (charge not completing) or near empty (cutoff too high).

- **Parameters.** \(R\_0\) and \(R\_1\) of a few hundred milliohms up to a few ohms are normal for small cells, \(\tau\_1\) of tens to a few hundred seconds.

- **Replay.** `replay --start-soc 1` runs the firmware estimator over the log and compares it against coulomb counting:

`synth` simulates the bench procedure on an existing model, quarter-rate tail included, which shows how well a profile identifies the parameters without running it:

```
python tools/fuel_gauge/fuel_gauge.py synth mycell.json synth.csv --lsb 0.0049
python tools/fuel_gauge/fuel_gauge.py fit synth.csv --name test -o fit.json
```

On simulated device usage (one sample a minute of a 1 mA load with 20 mA bursts, 5 mV voltage resolution), a model that matches the cell keeps the SOC within about 1%. That still holds with a ±10% current gain error or a ±0.3 mA offset. A start 20% off converges within minutes. On a real cell, the model error dominates, so the fit residual is the number to watch.

### Limitations of the method

- **Resistances from discharge pulses.** \(R\_0\) and \(R\_1\) are fitted on 0.5C discharge pulses, and the model uses them for charging at up to 1C too. Charge and discharge resistances differ, and so may the resistance at other rates, and the fixture resistance adds to the fitted \(R\_0\) unless it is measured. The model’s \(R\_0\) is the one to check on device charge logs.

- **Constant resistances.** \(R\_0\) and \(R\_1\) are fitted as one value over the whole SOC range, while a real cell’s rise near empty, so the fit there trades resistance error for OCV error.

- **One temperature.** Without logs at several temperatures, \(\kappa\) is the default 0.03 1/°C.

- **No hysteresis.** The procedure only discharges. The OCV after charging sits slightly higher than after discharging; the model has a single curve.

- **Rate-dependent capacity.** The capacity is what the profile draws down to the cutoff. A lighter load gets a little more out of the cell; the low-current tail reduces the difference.

- **Aging.** One fresh cell is measured, and capacity fade isn’t modelled.

Generated from PebbleOS [f4926c952](https://github.com/coredevices/pebbleos/commit/f4926c952bf9b82bce9e3cdb44645a59531c0ee9). This page is maintained in the pebbleos repository: [docs/libraries/fuel\_gauge/models/thevenin.md](https://github.com/coredevices/pebbleos/blob/f4926c952bf9b82bce9e3cdb44645a59531c0ee9/docs/libraries/fuel_gauge/models/thevenin.md).